STEP Gutter De-icing™ 3" wide radiant heating element is designed to solve problems with snow buildup, ice damming and creation of icicles. Make sure you provide proper drainage for the melted ice and snow in gutters.
STEP Gutter De-icing™ is protected by a 2-mil chemically, inherently inert and dielectric insulation so that the heating element can be installed directly in the gutter and in the downspout. This element can be used in the downspout to drain the water that would otherwise freeze in the gutters.
Ordering Information
Technical Specifications
Features
|
Element Length*
|
Power Supply (24V)
|
Watts
|
Amps 120V
|
Amps 240V
|
|
12ft (3.8m)
|
150VA
|
132
|
1.1
|
0.6
|
|
21ft (6.4m)
|
250VA
|
225
|
1.9
|
1.0
|
|
42ft (12.8m)
|
500VA
|
450
|
3.8
|
1.9
|
|
84ft (25.6m)
|
1000VA
|
900
|
7.5
|
3.8
|
|
126ft (38.5m)
|
1500VA
|
1350
|
11.3
|
5.6
|
* Maximum total element length per power supply.
Element length cut to order
Maximum Element Length by Strip: 21ft (12.8 m)
| Model: | MEP-7-30W-24V |
| Heating Element type: | Positive Temperature Coefficient (PTC) semi-conductor polymer |
| Width: | 3" (76 mm) |
| Length: | Cut to order |
| Max. Element Length: | 21ft (12.8 m) |
| Weight: | 0.06lb/ft (0.09 kg/m) |
| Thickness: | 3/64" (1.2 mm) |
| Output Wattage (at 24VAC): | 9.0 W/ft (29W/m) @68°F (20°C) 10.7 W/ft (35 W/m) @32°F (30°C) |
| Nominal Resistance: | 64 Ω/ft (19.5 Ω/m) @68°F (20°C) |
| Primary Draw on 230V: | 0.039 amps per foot (0.305) |